Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 58
Filter
1.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 42: e2023186, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550676

ABSTRACT

ABSTRACT Objective: To develop a rapid method for analysing polyphenols, which are potentially active antioxidants against neonatal oxidative stress, from small human milk (HM) volumes. Methods: Acid and alkaline extractions were compared using two dyes: Folin-Ciocalteu and Fast Blue BB. Linearity, sensitivity, recovery percentage, polyphenol content, precision, and stability were assessed in 14 HM samples and compared using the Kruskal-Wallis H test (p<0.05). The best technique was applied to 284 HM samples to determine their polyphenolic content and its association with maternal diet by multifactorial linear regression. Results: Acidic extraction successfully recovered the gallic acid reference standard, whereas alkaline extraction overestimated it. Calibration curves for all methods were linear (R2>0.96) up to 500 mg/L. All bicarbonate-based Folin-Ciocalteu methods assayed were stable and repeatable, whereas Fast Blue BB-based variants were not. HM polyphenols (mean=94.68 mg/L) positively correlated to the dietary intake of hydroxycinnamic acids, the most consumed polyphenolic family in this population. Conclusions: A bicarbonate-based Folin-Ciocalteu micromethod allowed the accurate determination of polyphenols in HM, which might be useful for translational research settings and HM banks.


RESUMO Objetivo: Desenvolver um método rápido para analisar polifenóis, que são antioxidantes potencialmente ativos contra o estresse oxidativo neonatal, em pequenos volumes de leite humano (LH). Métodos: Foram comparadas extrações ácidas e alcalinas usando dois corantes: Folin-Ciocalteu e Fast Blue BB. Foram avaliadas variáveis como linearidade, sensibilidade, percentagem de recuperação, teor de polifenóis, precisão e estabilidade em 14 amostras de LH, comparadas usando o teste de Kruskal-Wallis H (p<0,05). A melhor técnica foi aplicada a 284 amostras de LH para determinar seu teor polifenólico e sua associação com a dieta materna por regressão linear multifatorial. Resultados: A extração ácida recuperou com sucesso o padrão de referência do ácido gálico, enquanto a extração alcalina o superestimou. As curvas de calibração para todos os métodos foram lineares (R2>0,96) até os 500 mg/L. Todos os métodos testados baseados em Folin-Ciocalteu com bicarbonato foram estáveis e repetíveis, enquanto as variantes baseadas em Fast Blue BB não. Os polifenóis do HM (média=94,68 mg/L) correlacionaram-se positivamente com a ingestão dietética de ácidos hidroxicinâmicos, a família de polifenóis mais consumida nesta população. Conclusões: Um micrométodo baseado em bicarbonato de Folin-Ciocalteu permitiu a determinação precisa de polifenóis no HM, o que pode ser útil para configurações de pesquisa translacional e bancos de HM.

2.
Rev. latinoam. enferm. (Online) ; 31: e3839, ene.-dic. 2023. graf
Article in Spanish | LILACS, BDENF | ID: biblio-1431827

ABSTRACT

Objetivo: analizar el costo-efectividad y calcular la relación costoefectividad incremental del tratamiento multicapa compresivo con respecto al inelástico (bota de Unna y estiramiento corto) según la literatura actual. Método: estudio cuantitativo de costo-efectividad a través de un modelo con ayuda del software TreeAge® para la elaboración del árbol de decisión. Los supuestos anunciados se obtuvieron mediante el uso de datos secundarios de la literatura para estimar el costo y la efectividad de los parámetros asumidos. Para ello, se realizó una revisión sistemática de la literatura con metaanálisis. Resultados: el árbol de decisión, después del Roll Back, mostró que la terapia multicapa prevaleció sobre las alternativas en el caso base, presentó un costo intermedio por aplicación, pero obtuvo la mayor efectividad. El gráfico del análisis de costo-efectividad también demostró que había un dominio extendido de la bota de Unna sobre el vendaje de estiramiento corto. El análisis de sensibilidad reveló que el vendaje multicapa sigue siendo la alternativa con mayor costoefectividad, dentro del umbral de disposición a pagar. Conclusión: la alternativa con mayor costo-efectividad fue el vendaje multicapa, considerado estándar de oro en la literatura. La segunda alternativa con mayor costo-efectividad fue la bota de Unna, la terapia más utilizada en Brasil.


Objective: to analyze the cost-effectiveness and calculate the incremental cost-effectiveness ratio of multilayer compressive treatment in relation to inelastic (Unna boot and short stretch) therapy according to the current literature. Method: quantitative study about cost-effectiveness through modeling with the aid of TreeAge® software for construction of the decision tree. The anticipated assumptions were obtained by using secondary literature data to estimate the cost and effectiveness of the assumed parameters. A systematic literature review with meta-analysis was performed for this end. Results: the decision tree after Roll Back showed that the multilayer therapy dominated the alternatives in the base case, representing an intermediate cost per application, although with the highest effectiveness. The cost-effectiveness analysis graph also showed extended dominance of the Unna boot in relation to the short stretch bandage. The sensitivity analysis showed that multilayer bandage remains a more cost-effective alternative, within the threshold of willingness to pay. Conclusion: the most cost-effective alternative was multilayer bandage, considered the gold standard in the literature. The second most cost-effective alternative was the Unna boot, the most used therapy in Brazil.


Objetivo: analisar a custo-efetividade e calcular a razão de custoefetividade incremental do tratamento compressivo multicamadas em relação ao inelástico (bota de Unna e curto estiramento) de acordo com a literatura atual. Método: estudo quantitativo sobre custo-efetividade por meio de modelagem com auxílio do software TreeAge® para a construção da árvore de decisão. Os pressupostos anunciados foram obtidos pelo uso de dados secundários de literatura para estimativa do custo e efetividade dos parâmetros assumidos. Para tal, foi realizada uma revisão sistemática de literatura com metanálise. Resultados: a árvore de decisão, após Roll Back mostrou que a terapia multicamadas dominou as alternativas no caso-base, representando custo intermediário por aplicação, porém, com a maior efetividade. O gráfico da análise de custo-efetividade também mostrou uma dominância estendida da bota de Unna em relação à bandagem de curto estiramento. A análise de sensibilidade mostrou que a bandagem multicamadas permanece como alternativa mais custo-efetiva, dentro do limiar de disposição para pagar. Conclusão: a alternativa com maior custo-efetividade foi a bandagem multicamadas, considerada padrão ouro na literatura. A segunda alternativa mais custo-efetiva foi a bota de Unna, terapia mais utilizada no Brasil.


Subject(s)
Humans , Varicose Ulcer/therapy , Wound Healing , Brazil , Compression Bandages , Cost-Effectiveness Analysis
3.
Saúde debate ; 47(138): 393-403, jul.-set. 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1515573

ABSTRACT

RESUMO O cenário tecnológico no campo da saúde é um fato alarmante, mormente no contexto provocado pela Covid-19. Nessa conjuntura, a Fundação Oswaldo Cruz, por meio da Unidade de Bio-Manguinhos, e o Butantan foram protagonistas para o acesso universal, dialogando com estratégicas internacionais. No adensamento da discussão estratégica para Instituições Públicas de Produção e Inovação em Saúde (Ippis), o uso de diretrizes da Avaliação de Tecnologias em Saúde destaca-se como via de mudança paradigmática para a introdução de tecnologias no Sistema Único de Saúde (SUS) alinhada à visão de inovação de futuro em saúde consonante às demandas nacionais. Este artigo, desenvolvido metodologicamente mediante pesquisas descritiva qualitativa, bibliográfica, documental e trabalho de campo, buscou traçar simetrias e assimetrias baseado nas experiências coletadas em empresa farmacêutica global e instituição de referência nacional pública do campo de incorporação tecnológica em saúde. Como resultados, são explicitados pontos-chave para o fortalecimento técnico e político do Complexo Econômico-Industrial da Saúde, por meio da revisão organizacional das Ippis quanto a aspectos de inovação e de gestão, culminado na promoção de melhorias na Política de ciência, tecnologia e inovação em resposta ao desafio da sustentabilidade, efetividade e acesso no SUS.


ABSTRACT The technological scenario in the field of health is an alarming fact, especially in the context caused by COVID-19. In this context, the Oswaldo Cruz Foundation, through the Bio-Manguinhos Unit, and the Butantan Institute were protagonists for universal access, dialoguing with international strategies. In the strategic discussion for Public Institutions of Production and Innovation in Health (IPPIS), the use of guidelines of the Technological Assessment in Health stands out as a way of paradigmatic change for the introduction of technologies in the Unified Health System (SUS) in line with the vision of future innovation in health in accordance with national demands. This article, methodologically developed through qualitative descriptive research, bibliographical, documentary and field work, sought to trace symmetries and asymmetries based on the experiences collected in a global pharmaceutical company and a public national reference institution in the field of technological incorporation in health. As a result, key points are explained for the technical and political strengthening of the Health Economic-Industrial Complex, through the organizational review of the IPPIS regarding innovation and management aspects, culminating in the promotion of improvements in the science, technology and innovation policy in response to the challenge of sustainability, effectiveness and access in the SUS.

4.
J. bras. econ. saúde (Impr.) ; 14(Suplemento 2)20220800.
Article in Portuguese | LILACS, ECOS | ID: biblio-1412576

ABSTRACT

Objetivo: Abordar o contexto normativo quanto aos processos de participação social nas fases de Pesquisa, Desenvolvimento e Inovação (PD&I) e aos processos de regulação sanitária e de avaliação para incorporação de tecnologias no Sistema Único de Saúde (SUS). Métodos: Pesquisa exploratória descritiva com revisão dos referenciais normativos e análise documental: i) nos marcos regulatórios de inovação brasileiros; ii) na regulação sanitária pela Agência Nacional de Vigilância Sanitária (Anvisa); e iii) na avaliação e incorporação de dispositivos médicos na Comissão Nacional de Incorporação de Tecnologias em Saúde no SUS (Conitec). Resultados: Nos sites das instituições governamentais de fomento à Ciência, Tecnologia e Inovação (CT&I) vinculadas ao Ministério da Ciência, Tecnologia e Inovações (MCTI), observaram-se mecanismos de participação social estabelecidos na legislação. No contexto regulatório, a participação social se insere desde a construção dos regulamentos até etapas-chave do ciclo de vida da tecnologia. Na avaliação de tecnologias, verificou-se ampliação das estratégias de participação, a exemplo da "perspectiva do paciente" na plenária. Entre 64 chamadas públicas realizadas, cinco foram sobre dispositivos médicos. Conclusão: Evidenciou-se a importância da participação social em todas etapas do ciclo de vida dos dispositivos médicos, tendo em vista as especificidades dessas tecnologias. A Anvisa e a Conitec têm ampliado os mecanismos de participação para além dos preconizados em lei. Já nas etapas de PD&I, as iniciativas são incipientes, sendo localizadas ações conforme previsão legal. A ampliação de mecanismos de participação efetiva favorece a construção de soluções para minimizar os desafios de saúde, além de promover maior transparência, valor para a sociedade e confiança nas decisões em saúde brasileira.


Objective: To address the normative context regarding the processes of social participation in the phases of Research, Development and Innovation (RD&I), sanitary regulation and assessment for incorporation of technologies into SUS. Methods: Descriptive exploratory research with review of normative references and document analysis: i) in the regulatory milestones of Brazilian Innovation; ii) sanitary regulation by the National Health Surveillance Agency (Anvisa); and iii) in the assessment and incorporation of medical devices in the National Committee for Health Technology Incorporation into SUS (Conitec). Results: In the websites of government institutions that support RD&I linked to the MCTI, mechanisms of social participation established in the legislation were observed. In the regulatory context, social participation is inserted since the construction of regulations until key stages of the technology lifecycle. In the assessment of medical devices, we verified an expansion of engagement strategies, such as the "patient perspective" in the plenary meeting. From its 64 public calls, five were directed to medical devices. Conclusion: The importance of social participation in the


Subject(s)
Technology Assessment, Biomedical , Health Sciences, Technology, and Innovation Management , Social Participation , Health Economic-Industrial Complex
5.
J. bras. econ. saúde (Impr.) ; 14(Suplemento 2)20220800.
Article in Portuguese | ECOS, LILACS | ID: biblio-1412774

ABSTRACT

Objetivo: Pretendeu-se mapear os bancos de dados governamentais em dispositivos médicos, na perspectiva pública com o intuito de contribuir como fonte para gerar dados de mundo real (RWD) e potencial para subsidiar estudos de Avaliação de Tecnologias em Saúde (ATS). Métodos: Realizada revisão narrativa na base de dados do Embase. Os critérios para inclusão de elegibilidade foram: i) dimensão ampla de RDW nos processos de gestão de tecnologias; e ii) aplicação de RDW em processos regulatórios, cobertura e ATS. Também foram consultados os sistemas do Ministério da Saúde e da Anvisa. Resultados: A busca retornou 1.185 resultados; após leitura dos resumos, foram selecionados 29 artigos, sendo 5 incluídos. Na consulta ao catálogo do Datasus, foram localizados 262 sistemas informatizados; após análise da descrição sumária e principais objetivos, foram selecionados 12 sistemas que geram dados sobre dispositivos médicos. A falta de interoperabilidade dos sistemas é recorrente e a ausência de uma nomenclatura padronizada é um desafio a mais. Conclusão: Há crescente discussão do uso de RWD para subsidiar ATS em todo o ciclo de vida tecnológico, desde regulação até monitoramento do uso, como também para subsidiar análises de custo-efetividade e benefícios clínicos. Assim como nos demais países, o Brasil sistematizou inicialmente os dados administrativos para atender às demandas comerciais e financeiras. Os sistemas não geram dados dos resultados clínicos. São disponibilizados dados das tecnologias dispensadas e dos valores repassados e não são coletadas as informações dos benefícios do uso dessas tecnologias. Com a evolução dos métodos de ATS, a utilização de RWD tornou-se relevante.


Objective: It was intended to map government databases on medical devices, in the public perspective, in order to contribute as a source to generate real world data (RWD) and potential to subsidize Health Technology Assessment (HTA) studies. Methods: A narrative review was carried out in the Embase database. The criteria for inclusion of eligibility were: i) broad dimension of RDW in technology management processes; and ii) application of RDW in regulatory processes, coverage and HTA. The systems of the Ministry of Health and Anvisa were also consulted. Results: Results: The search returned 1,185 results, after reading the abstracts, 29 articles were selected, 5 of which were included. The catalog of Datasus database were consulted, 262 summaries with the description and the main objectives were analyzed, 12 systems were selected systems that generate medical devices. The lack of interoperability of systems is recurrent and the absence of a standardized nomenclature is an additional challenge. Conclusion: There is a growing discussion about the use of RWD to subsidize HTA throughout the technological life cycle, from regulation to monitoring of use, as well as to subsidize the examination of cost-effectiveness and clinical benefits. As in other countries, Brazil has systematized administrative data for commercial and financial data demands. The systems do not generate data on clinical outcomes. Data provided are on dispensed technologies, on transferred values and are not collected on the benefits of using these technologies. With the evolution of HTA methods, the use of RWD has become relevant.


Subject(s)
Technology Assessment, Biomedical , Equipment and Supplies , Access to Essential Medicines and Health Technologies , Public Reporting of Healthcare Data
6.
Arch. méd. Camaguey ; 26: e8745, 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1403311

ABSTRACT

RESUMEN Introducción: La evaluación externa de la calidad es un procedimiento que compara los resultados de varios laboratorios que analizan la misma muestra, con el propósito de evaluar el desempeño analítico y asegurar la calidad. La provincia Camagüey fue incluida en forma permanente en el programa de evaluación externa de la calidad desde que se inició hasta que por diferentes dificultades nacionales y provinciales dicho programa no pudo continuar. Desde entonces, el comité de calidad de la provincia decidió organizar alternativas de evaluación con este propósito. En el 2016 se aplicó una nueva propuesta de evaluación en los laboratorios clínicos del nivel primario de atención. Objetivo: Evaluar la calidad de los resultados obtenidos en el procesamiento de los componentes de química clínica, en los laboratorios del nivel primario de la provincia Camagüey. Métodos: Se realizó un estudio descriptivo transversal desde septiembre de 2017 hasta julio de 2018, el universo estuvo constituido por todos los laboratorios clínicos de la provincia Camagüey y se trabajó con una muestra no probabilística de 14 laboratorios. Resultados: El desempeño analítico de colesteroles, glucemia y creatinina fue aceptable y los triglicéridos no aceptables, un policlínico del municipio Camagüey mostró el menor por ciento de error de medida de precisión y de exactitud. Conclusiones: Los resultados de los colesteroles mostraron los mejores desempeños analíticos y los resultados obtenidos fueron más exactos que precisos en los componentes evaluados. Fue elevado el por ciento de participación de los laboratorios 04 y 09 durante todo el tiempo que duró el estudio.


ABSTRACT Introduction: External quality assessment is a procedure that compares the results of several laboratories that analyze the same sample, with the purpose of evaluating analytical performance and assuring quality. Camagüey participated constantly in the external quality assessment program from the beginning until, due to different national and provincial difficulties, said program could not continue. Since then, the province(s quality committee decided to organize assessment alternatives for this purpose. In 2016, a new assessment proposal was applied in clinical laboratories al the primary level of care. Objective: To evaluate the quality of the results obtained in the processing of clinical chemistry components in primary level laboratories in the province of Camagüey. Methods: A cross-sectional descriptive study was carried out from September 2017 to July 2018, the universe consisted of all clinical laboratories in the province of Camagüey and a non-probabilistic sample of 14 laboratories was used. Results: The analytical performance of cholesterol, blood-glucose level and creatinine was acceptable and triglycerides were unacceptable. A polyclinic in the municipality of Camagüey showed the lowest percentage of precision and accuracy measurement error. Conclusions: The cholesterols results showed the best performances and the results obtained were more exact than precise in the evaluated components. The participation percentage of laboratories 04 and 09 was high throughout the duration of the study.

8.
Acta neurol. colomb ; 37(3): 145-153, jul.-set. 2021. tab, graf
Article in Spanish | LILACS | ID: biblio-1345054

ABSTRACT

RESUMEN INTRODUCCIÓN: La esclerosis múltiple es una enfermedad neuroinflamatoria, crónica, degenerativa e incurable, asociada a pérdida neuronal, grados crecientes de discapacidad y deterioro cognoscitivo. Su manejo conlleva grandes costos para los sistemas de salud y la sociedad en general. OBJETIVO: Evaluar la eficacia y la seguridad del uso del rituximab en el manejo de la esclerosis múltiple. MATERIALES Y MÉTODOS: Revisión de la literatura y evaluación de la tecnología en salud tipo mini-HTA en red colaborativa con el Comité de Esclerosis Múltiple de la Asociación Colombiana de Neurología y el Instituto Global de Excelencia Clínica. RESULTADOS: Se identificaron 27 referencias de texto completo para el análisis de la seguridad y la eficacia del rituximab en el manejo de la esclerosis múltiple. Se utilizaron análisis de costos, indicadores epidemiológicos y estudios pivótales de rituximab. CONCLUSIÓN: La evidencia analizada confirma que la terapia con rituximab es efectiva y segura en el manejo de las formas de esclerosis múltiple remitente-recurrente (EMRR) y esclerosis múltiple primaria-progresiva (EMPP), con menor tasa de eventos adversos y tasas de interrupción o abandono del tratamiento más bajas que otras terapias modificadoras de la enfermedad (TME).


SUMMARY INTRODUCTION: Multiple sclerosis is a neuroinflammatory, chronic, degenerative, and incurable disease, associated with neuronal loss, increasing degrees of disability, and cognitive control. Its treatment causes great costs for health systems and society in general. OBJECTIVE: To evaluate the efficacy and safety of the use of rituximab in the management of multiple sclerosis. MATERIALS AND METHODS: Literature review and evaluation of mini-HTA type health technology in a collaborative network with the Multiple Sclerosis Committee of the Colombian Association of Neurology and the Global Institute of Clinical Excellence. RESULTS: 27 full-text references were identified for the safety and efficacy analysis of rituximab in the management of multiple sclerosis. Cost analysis, epidemiological indicators, and pivotal studies of rituximab were incorporated into the analysis. CONCLUSION: The evidence analyzed confirms that rituximab therapy is effective and safe in the management of the forms of Recurrent-Remittent Multiple Sclerosis (RRMS) and Primary-Progressive Multiple Sclerosis (PPMS), with a lower rate of adverse events and discontinuation or withdrawal rates of treatment lower than other disease-modifying therapies.


Subject(s)
Safety , Technology Assessment, Biomedical , Therapeutics , Efficacy , Rituximab , Multiple Sclerosis
9.
Rev. bras. med. fam. comunidade ; 16(43): 2601, 20210126.
Article in Portuguese | LILACS | ID: biblio-1282269

ABSTRACT

La pandemia de COVID-19 ha permitido analizar crisis sistémicas en diferentes aspectos de la vida social. La crisis de la racionalidad biomédica parece ser reiterada, por un lado, por la narrativa estadística dominante a través de la contabilización de casos y muertes todos los días. Por otro lado, debido a la escasez, hasta ahora, de evidencia científica sobre pruebas de diagnóstico y tratamientos farmacológicos para la nueva enfermedad. La profusión de protocolos clínicos y la necesidad de lidiar con tanta incertidumbre al encontrarse con pacientes que sufren son elementos que exigen volver a una pregunta fundamental, especialmente para la medicina familiar y comunitaria: ¿cómo ejercer la atención médica en un contexto de rupturas de vínculos de confianza?


The COVID-19 pandemic has made it possible to analyze systemic crises in different aspects of social life. The crisis of Biomedical Rationality seems to be reiterated, on one hand, by the dominant statistical narrative through the accounting of cases and everyday deaths. On the other hand, due to the scarcity, so far, of scientific evidence about diagnostic tests and drug treatments for the new disease. The profusion of clinical protocols and the need to deal with such uncertainty when meeting with suffering patients are elements that demand a return to a fundamental question, especially for Family Medicine: how to exercise Health Care in a context of ruptures of bonds of trust between patients and physicians?


A pandemia do COVID-19 tem permitido analisar crises sistêmicas em diferentes aspectos da vida social. A crise da Racionalidade Biomédica parece ser reiterada, de um lado pela narrativa estatística dominante por meio da contabilidade de casos e mortes a cada dia. Por outro lado, pela escassez, até o momento, de evidências científicas acerca de exames diagnósticos e tratamentos medicamentosos para a nova doença. A profusão de protocolos clínicos e a necessidade de lidar com tamanha incerteza no encontro com pacientes em sofrimento são elementos que exigem retomar uma pergunta fundamental, em especial para a Medicina de Família e Comunidade: como exercitar o Cuidado em Saúde em um contexto de rupturas dos vínculos de confiança?


Subject(s)
Physician-Patient Relations , Technology Assessment, Biomedical , Clinical Protocols , Coronavirus Infections , Evidence-Based Medicine , COVID-19
10.
Rev. Esc. Enferm. USP ; 55: e03712, 2021. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1250729

ABSTRACT

ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher's exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice.


RESUMEN Objetivo: Analizar la usabilidad de dos modelos de bombas de infusión en una Unidad de Cuidados Intensivos Pediátricos. Método: Estudio transversal con abordaje descriptivo exploratorio cuantitativo. Se realizó una tarea en ambiente controlado utilizando la bomba de infusión con 72 integrantes del equipo de enfermería de agosto a septiembre de 2018. Como base, se siguió la guía metodológica para los estudios de evaluación de Equipos de Asistencia Médica y el modelo de calidad en uso propuesto por NBR ISO/IEC 9126-1 Se utilizó análisis estadístico descriptivo, aplicando Test Exacto de Fisher, Test Binomial y Test de Mann-Whitney. Resultados: Hubo 91,7% de tareas completadas. El modelo de bomba de infusión-2 se asoció (p <0,001) con la operatividad, las tareas cumplidas con no conformidades, el uso de la calculadora manual (medida de efectividad) y el tiempo para completar la tarea (medida de eficiencia). Conclusión: Las medidas de eficacia y eficiencia pueden mostrar un mejor contexto de usabilidad de las bombas de infusión e identificar fallas de interacción con el equipo de enfermería para mejorar en la práctica asistencial.


RESUMO Objetivo: Analisar a usabilidade de dois modelos de bomba de infusão em Unidade de Terapia Intensiva Pediátrica. Método: Estudo com delineamento transversal de abordagem quantitativa do tipo descritivo exploratório. Realizou-se em um ambiente controlado uma tarefa utilizando a bomba de infusão com 72 integrantes da equipe de enfermagem no período de agosto a setembro de 2018. Como base, seguiu-se a diretriz metodológica para estudos de avaliação de Equipamentos Médicos-Assistenciais e o modelo de qualidade em uso proposto pela NBR ISO/IEC 9126-1. Utilizou-se a análise estatística descritiva, aplicando o Teste Exato de Fisher, o Teste Binomial e o Teste de Mann-Whitney. Resultados: Constataram-se 91,7% de tarefas cumpridas. O modelo da bomba de infusão-2 apresentou associação (p < 0,001) com a operacionalização, tarefas cumpridas com não conformidades, uso da calculadora manual (medida eficácia) e o tempo para cumprir a tarefa (medida eficiência). Conclusão: Medidas de eficácia e eficiência podem evidenciar um melhor contexto de usabilidade de bombas de infusão e identificar falhas de interação com a equipe de enfermagem a serem aprimoradas na prática assistencial.


Subject(s)
Pediatric Nursing , Intensive Care Units, Pediatric , Quality of Health Care , Technology Assessment, Biomedical , Infusion Pumps , Ergonomics
11.
Rev. latinoam. enferm. (Online) ; 29: e3426, 2021. tab
Article in English | BDENF, LILACS | ID: biblio-1251887

ABSTRACT

Objective: to compare the quality of the Nursing process documentation in two versions of a clinical decision support system. Method: a quantitative and quasi-experimental study of the before-and-after type. The instrument used to measure the quality of the records was the Brazilian version of the Quality of Diagnoses, Interventions and Outcomes, which has four domains and a maximum score of 58 points. A total of 81 records were evaluated in version I (pre-intervention), as well as 58 records in version II (post-intervention), and the scores obtained in the two applications were compared. The interventions consisted of planning, pilot implementation of version II of the system, training and monitoring of users. The data were analyzed in the R software, using descriptive and inferential statistics. Results: the mean obtained at the pre-intervention moment was 38.24 and, after the intervention, 46.35 points. There was evidence of statistical difference between the means of the pre- and post-intervention groups, since the p-value was below 0.001 in the four domains evaluated. Conclusion: the quality of the documentation of the Nursing process in version II of the system was superior to version I. The efficacy of the system and the effectiveness of the interventions were verified. This study can contribute to the quality of documentation, care management, visibility of nursing actions and patient safety.


Objetivo: comparar a qualidade da documentação do processo de enfermagem em duas versões de um sistema de apoio à decisão clínica. Método: estudo quantitativo, quase-experimental do tipo antes e depois. O instrumento utilizado para mensurar a qualidade dos registros foi o Quality of Diagnoses, Interventions and Outcomes Versão Brasileira, que possui quatro domínios e escore máximo de 58 pontos. Foram avaliados 81 registros na versão I (pré-intervenção), 58 registros da versão II (pós-intervenção) e comparados os escores obtidos nas duas aplicações. As intervenções consistiram em planejamento, implantação piloto da versão II do sistema, treinamento e acompanhamento dos usuários. Os dados foram analisados no software R, utilizando-se estatística descritiva e inferencial. Resultados: a média obtida na pré-intervenção foi de 38,24 e pós-intervenção, 46,35 pontos. Houve evidências de diferença estatística entre as médias dos grupos pré e pós-intervenção, visto que o valor-p foi menor que 0,001 nos quatro domínios avaliados. Conclusão: a qualidade da documentação do processo de enfermagem na versão II do sistema foi superior à versão I. A eficácia do sistema e a efetividade das intervenções foram comprovadas. Este estudo pode contribuir para a qualidade da documentação, gerenciamento do cuidado, visibilidade das ações de enfermagem e segurança do paciente.


Objetivo: comparar la calidad de la documentación del proceso de Enfermería en dos versiones de un sistema de apoyo a la decisión clínica. Método: estudio cuantitativo y cuasi-experimental del tipo antes y después. El instrumento que se usó para medir la calidad de los registros fue la versión brasileña del Quality of Diagnoses, Interventions and Outcomes, que contiene cuatro dominios y puntaje máximo de 58 puntos. Se evaluaron 81 registros en la versión I (pre-intervención), 58 registros de la versión II (post-intervención) y se compararon las puntuaciones logradas en las dos aplicaciones. Las intervenciones consistieron en planificar, implementar de forma piloto la versión II del sistema, entrenar y realizar un seguimiento a los usuarios. Los datos se analizaron en el software R, utilizando estadística descriptiva e inferencial. Resultados: el promedio obtenido en el momento pre-intervención fue de 38,24 y en la post-intervención fue de 46,35 puntos. Se registraron evidencias de diferencia estadística entre los promedios de los grupos pre- y post-intervención, visto que el valor-p fue menor que 0,001 en los cuatro dominios evaluados. Conclusión: la calidad de la documentación del proceso de Enfermería en la versión II del sistema fue superior a la versión I. Se comprobó la eficacia del sistema y la efectividad de las intervenciones. Este estudio pudo contribuir para la calidad de la documentación, gerenciamiento de la atención, visibilidad de las acciones de Enfermería y seguridad del paciente.


Subject(s)
Technology Assessment, Biomedical , Decision Support Systems, Clinical , Nursing Informatics , Electronic Health Records , Standardized Nursing Terminology , Nursing Process
12.
Saúde debate ; 44(127): 1255-1276, Out.-Dez. 2020. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1156910

ABSTRACT

RESUMO A Avaliação de Tecnologias em Saúde (ATS) respalda políticas públicas na gestão de tecnologias em diversos países. No Brasil, a institucionalização da ATS se iniciou em 2000, no Ministério da Saúde, e contou com a participação da Agência Nacional de Saúde Suplementar (ANS). Contudo, o sistema público e a saúde suplementar trilharam diferentes caminhos. Processos distintos de ATS podem gerar retrabalho, ineficiência e aumentar as inequidades entre o público e o privado. O objetivo desta pesquisa foi identificar a dualidade entre o público e o privado relativa aos modelos de ATS implantados no País. Realizou-se uma revisão de escopo da literatura no período de 2000 a 2019 nas bases de dados Medline, Scopus, Web of Science e Lilacs. Também se realizou análise de documentos da ANS relativos ao processo de ATS na saúde suplementar. A revisão da literatura constatou a escassez de artigos sobre o tema, enquanto a análise documental permitiu traçar uma linha do tempo com os principais marcos referentes ao processo de ATS da Agência. Concluiu-se que a coordenação nacional de um modelo de ATS é desejada, visando a aumentar a transparência das instituições, a maior credibilidade das suas decisões, maior eficiência do processo e proporcionar maior equidade.


ABSTRACT Health Technology Assessment (HTA) supports public policies on technology management in several countries. In Brazil, the institutionalization of HTA began in 2000 at the Ministry of Health, and had the participation of the National Regulatory Agency for Private Health Insurance (ANS). However, the public and the private systems have taken different paths. Different HTA processes can generate rework, inefficiency and increase inequities between the public and the private sectors. The objective of this research was to identify the duality between those two sectors regarding the current models of HTA implemented in the country. A scoping review of the literature was carried out from 2000 to 2019, in the Medline, Scopus, Web of Science and Lilacs databases. ANS documents were also analyzed, relating to the HTA process in private health insurance sector. The literature review found a shortage of articles on the topic, while the document analysis allowed to draw a timeline with the main milestones related to the Agency's HTA process. It was concluded that the national coordination of an HTA model is desired, aiming at increasing the transparency of the institutions, the greater credibility of their decisions, greater efficiency of the process, and providing greater equity.

13.
Rev. peru. med. exp. salud publica ; 37(2): 320-326, abr.-jun. 2020.
Article in Spanish | LILACS | ID: biblio-1127153

ABSTRACT

RESUMEN El Instituto de Evaluación de Tecnologías en Salud e Investigación (IETSI) del Seguro Social de Salud (EsSalud) ha desarrollado siete informes breves mediante revisiones rápidas de evidencia sobre los agentes potencialmente terapéuticos contra el SARS-CoV-2 con la finalidad de brindar información actual y relevante para los decisores, clínicos, investigadores y la comunidad académica en el Perú. Los agentes terapéuticos evaluados incluyeron cloroquina/hidroxicloroquina, lopinavir/ritonavir, tocilizumab, oseltamivir, interferón, atazanavir y plasma anti-SARS-CoV-2. La identificación de evidencia incluyó la revisión de las bases electrónicas PubMed y Cochrane Library. Adicionalmente, se realizó una búsqueda manual en las páginas web de grupos dedicados a la investigación y educación en salud, así como, en las principales sociedades o instituciones especializadas, como la Organización Mundial de la Salud (OMS) y los Centros para el Control y la Prevención de Enfermedades (CDC, por sus siglas en inglés). Asimismo, para disminuir el sesgo de publicación, se buscó en las páginas web www.clinicaltrials.gov y http://apps.who.int/trialsearch, para identificar ensayos clínicos en desarrollo o que no hayan sido publicados aún. Finalmente, se consideró extraer información con una estrategia de «bola de nieve¼ mediante la revisión de las listas de referencias de las revisiones sistemáticas, estudios primarios y revisiones narrativas que sean de relevancia. A la fecha de la última revisión (27 de marzo de 2020), no se dispone de evidencia para recomendar un medicamento específico para el tratamiento de pacientes con COVID-19. Se necesita de mayor evidencia, preferentemente ensayos clínicos de buena calidad, para la toma de decisiones terapéuticas contra el SARS-CoV-2.


ABSTRACT The Instituto de Evaluación de Tecnologías en Salud e Investigación (IETSI) of the Seguro Social de Salud (EsSalud) has completed seven brief reports by means of rapid reviews of evidence regarding the potentially effective therapies against SARS-CoV-2 in order to provide current and relevant information for decision makers, clinicians, researchers and the academic community in Peru. The therapeutic agents evaluated were chloroquine/hydroxychloroquine, lopinavir/ritonavir, tocilizumab, oseltamivir, interferon, atazanavir and anti SARS-CoV-2 serum. Evidence identification included the review of PubMed and Cochrane Library electronic databases. Additionally, manual search was carried out on websites from groups dedicated to research and education on health, as well as in the main specialized societies or institutions, such as, the World Health Organization (WHO) and Centers for Disease Control and Prevention (CDC). Furthermore, in order to reduce publication bias, the websites: www.clinicaltrials.gov and http://apps.who.int/trialsearch were searched to identify in-progress or unpublished clinical trials. Finally, a "snowball" strategy was performed by reviewing the reference lists of the systematic reviews, primary studies and selected narrative reviews to identify relevant information. The latest review (March 27, 2020) showed that there is no evidence to recommend any medication for patients´ treatment with COVID-19. More evidence, preferably high-quality randomized clinical trials, is needed for decision-making against SARS-CoV-2.


Subject(s)
Humans , Pneumonia, Viral/drug therapy , Coronavirus Infections/drug therapy , Antiviral Agents/administration & dosage , Peru , Pneumonia, Viral/virology , Treatment Outcome , Coronavirus Infections/virology , Pandemics , COVID-19
14.
Rev. cuba. invest. bioméd ; 39(1): e385, ene.-mar. 2020. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1126573

ABSTRACT

Introducción: La correcta determinación de la longitud de trabajo es uno de los principales factores determinantes para el éxito de los tratamientos endodónticos. Objetivo: valorar si es precisa la determinación de la longitud de trabajo de un localizador de ápice electrónico en dientes monorradiculares. Métodos: se realizó un estudio experimental exploratorio in vivo, donde se determinó la longitud de trabajo en 141 conductos monorradiculares en pacientes con indicación de exodoncia. Se determinó la longitud de trabajo con un localizador de ápice electrónico iPex II(NSK). Cuando el localizador marcó que la lima se encontraba en el ápice, sin retirar el instrumento del conducto se procedió a fijarla. Se realizó la extracción con precaución y, posteriormente, se desgastó una pared proximal del tercio apical hasta que se pudo observar la lima en el interior del conducto, con auxilio de una lupa. La longitud de trabajo fue aceptable cuando el localizador determinó que estaba entre 0,5-1,5 mm del límite cemento-dentina-conducto; corto cuando estaba a más de 1,5 mm y largo cuando se observó que sobrepasaba el límite cemento-dentina-conducto. Resultados: fue aceptable la precisión en 135 (95,7 por ciento) mediciones y solo 13 (9,2 por ciento) conductos tuvieron inestabilidad, con una relación existente entre la precisión y la inestabilidad de las mediciones. Se observó que 88 (62,4 por ciento) conductos con secreciones obtuvieron un aceptable en la determinación de la longitud de trabajo, mientras que solo 3 (2,1 por ciento) conductos con secreciones tuvieron mediciones cortas. La presencia de secreciones no fue significativa para evaluar la precisión. Conclusiones: Las mediciones de las longitudes de trabajo empleando el localizador estudiado fueron mayormente de precisión aceptable y no inestables. Del mismo modo, la presencia de secreciones en el interior de los conductos radiculares no afectó significativamente la precisión del localizador en cuestión(AU)


Introduction: The correct determination of working length is one of the main determining factors for the success of endodontic treatments. Objective: to assess the accuracy when determining the working length of an electronic apex locator. Objective: To assess the accuracy of the determination of the working length of an electronic apex locator in monoradicular teeth. Material and methods: An exploratory experimental study was carried out in vivo where the working length was taken in 141 monoradicular root canals of patients with indication of extraction. Working length was determined using iPex II electronic apex locator (NSK). When the locator marked that the file was at the apex, without removing the instrument from the duct, it was fixed. The extraction was performed with caution and subsequently a proximal wall of the apical third was worn down until the file was observed inside the duct, observed and studied with the help of a magnifying glass. The working length was acceptable when the locator determined that it was between 0.5-1.5 mm of the cement-dentin-duct limit; short when it was more than 1.5 mm and long when it was observed that it exceeded the cement-dentine-duct limit. Results: The accuracy of 95.7 percent (135) of the measurements was acceptable and only 13(9.2 percent) ducts had instability, with an existing relationship between the accuracy and instability of the measurements. It was observed that 88(62.4 percent) ducts with secretions obtained an acceptable one in the determination of the length of work. Only 3 (2.1 percent) ducts with secretions had short measurements. The presence of secretions was not significant to assess the accuracy. Conclusions: The measurements of the working lengths using the locator studied were, almost entirely, of acceptable precision and were practically unstable. Similarly, the presence of secretions inside the root canals did not significantly affect the accuracy of the localizer in question(AU)


Subject(s)
Humans , Surgery, Oral , Longitudinal Studies , Tooth Apex/diagnostic imaging , Electronics
15.
Rev. saúde pública (Online) ; 54: 136, 2020. tab, graf
Article in English | LILACS, BBO, SES-SP | ID: biblio-1145059

ABSTRACT

ABSTRACT OBJECTIVE The study aims to characterize and discuss the processes of patient and public involvement (PPI) in the Brazilian Health Regulatory Agency (Anvisa), the National Committee for Health Technology Incorporation (Conitec), and the National Agency for Supplementary Health (ANS) in Brazil. METHODS This is an exploratory, descriptive, and comparative study, conducted by analyzing the public documents and regulation of the three institutions. RESULTS The mechanisms for PPI included public consultations, public hearings, participation in advisory committees, and health technology evaluation requests. Anvisa conducted 187 public consultations between 1999 and 2018, gathering 10,699 contributions. In total, 76 (41%) public consultations did not present information about the contributions received. Conitec carried out 234 public consultations and received 53,174 contributions between 2011 and 2018. It was identified that 70 (23%) recommendations from Conitec did not go through public consultation, and 26 (8%) recommendations changed after public consultation. Recommendation changes seemed to have occurred especially in cases with a greater number of contributions in the public consultation process. ANS conducted eight public consultations regarding the list of health procedures and events covered by health insurances between 2000 and 2018, and it received 31,498 contributions. For three public consultations, there was no information about the number of contributions received. CONCLUSIONS There are regulatory advances and institutional activity supporting PPI in highly technical decision-making processes in Brazil, although heterogeneously among the analyzed institutions. The power of PPI to influence health technology deliberative processes still requires in-depth studies, including the characterization of stakeholders and the legitimacy of decisions.


RESUMO OBJETIVO Caracterizar e discutir os processos formais de participação social previstos e implementados pelas instituições Agência Nacional de Vigilância Sanitária (Anvisa), Comissão Nacional de Incorporação de Tecnologias no SUS (Conitec) e Agência Nacional de Saúde Suplementar (ANS). MÉTODOS Estudo exploratório, descritivo, comparativo, conduzido por meio de análise de documentos publicados até 2018 no sítio eletrônico e da legislação específica de cada instituição. RESULTADOS Os espaços de participação social identificados incluem a representação em colegiados e participação direta por meio de uma demanda inicial ou em consultas públicas, audiências públicas e ouvidorias. A Anvisa conduziu 187 consultas públicas entre 1999 e 2018, e contabilizou 10.699 contribuições. Em 76 (41%) consultas públicas não há informações sobre as contribuições recebidas. A Conitec conduziu 234 consultas públicas, e recebeu 53.174 contribuições entre 2011 e 2018. Identificou-se que 70 (23%) recomendações da Conitec foram emitidas sem consulta pública, e 26 (8%) recomendações preliminares foram alteradas após consulta pública. As alterações de recomendação aconteceram especialmente em casos com grande volume de contribuições. A ANS conduziu 8 consultas públicas sobre o rol de procedimentos e eventos em saúde entre 2000 e 2018, e recebeu pelo menos 31.498 contribuições. Em três consultas públicas não há informações sobre o número de contribuições recebidas. CONCLUSÕES Observa-se recente avanço normativo e de desempenho institucional em favor da participação social em espaços decisórios notadamente técnicos, embora de forma bastante heterogênea entre as instituições analisadas. O poder deliberativo da participação social de influenciar as decisões em saúde ainda necessita de estudo aprofundado, incluindo a caracterização dos participantes e a legitimidade das decisões subsequentes.


Subject(s)
Humans , Patient Participation , Community Participation , Biomedical Technology , Decision Making , Brazil
16.
Rev. bras. enferm ; 73(5): e20180942, 2020. tab, graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1115341

ABSTRACT

ABSTRACT Objectives: to compare the effectiveness of the decentralized automated drug dispensing system with pockets. Methods: an effectiveness study based on a systematic review guided by the question: for patients admitted to hospital units, is the use of automated drug dispensing effective for reducing medication errors when compared to manual unit dose dispensing? The evidence was evaluated by the Grading of Recommendations Assessment, Development and Evaluation and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses instrument, used in the report. Results: the sample was composed of 15 studies and none of them directly compared both technologies; however, the meta-analysis showed that there is no difference in effectiveness between them [OR 1.03 95%CI (0,12 - 8,99)]. Conclusions: the conclusion is that the recommendation in favor of the automated dispensing system is weak.


RESUMEN Objetivos: comparar la eficacia del sistema automatizado de distribución descentralizada de medicamentos por armario. Métodos: se trata de un estudio de efectividad basado en una revisión sistemática guiada por el tema: Para los pacientes ingresados en los hospitales, ¿el uso del dispensario electrónico es eficaz para reducir errores de medicación en comparación con la dispensación manual por dosis unitaria? El conjunto de la evidencia se evaluó según los sistemas GRADE (evaluación de la calidad de la evidencia y graduación de la fuerza de las recomendaciones) y PRISMA (elementos de informes preferidos para los protocolos de revisión sistemática y metaanálisis) usado en el informe. Resultados: la muestra estaba compuesta de 15 estudios y ninguno comparó directamente las tecnologías; sin embargo, el metaanálisis mostró que no existe diferencia de la eficacia entre ellas [OR 1.03 IC 95% (0,12 - 8,99)]. Conclusiones: se ultima que la recomendación es débil a favor del dispensario electrónico.


RESUMO Objetivos: comparar a efetividade do sistema automatizado de distribuição descentralizada de medicamentos por armário. Métodos: trata-se de estudo de efetividade embasado por revisão sistemática, norteada pela questão: Para pacientes internados em unidades hospitalares, o uso de dispensário eletrônico é efetivo para a redução de erros de medicação comparado à dispensação manual por dose unitária? O conjunto da evidência foi avaliado pelo Grading of Recommendations Assessment, Development and Evaluation, sendo o instrumento Preferred Reporting Items for Systematic Reviews and Meta-Analyses usado no relatório. Resultados: a amostra foi composta por 15 estudos e nenhum deles comparou diretamente as tecnologias, contudo, a metanálise revelou que não existe diferença de efetividade entre elas [OR 1.03 IC 95% (0,12 - 8,99)]. Conclusões: conclui-se que a recomendação é fraca a favor do dispensário eletrônico.

17.
Rev. latinoam. enferm. (Online) ; 28: e3330, 2020. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1115738

ABSTRACT

Objective: to assess the technical quality of a decision support system for reception and risk classification in obstetrics. Method: a methodological study of assessment of the system. 12 nurses and 11 information technology (IT) professionals were invited to evaluate the Obstetrics Reception and Risk Classification System (Sistema de Acolhimento e Classificação de Risco em Obstetrícia, SACR-O). Based on the standards of the International Organization for Standardization, the minimum number of evaluators and the characteristics to be evaluated were established: functional suitability, reliability, usability, performance efficiency, compatibility, safety, maintainability, and portability. The characteristics assessed should be given a ≥70% positive assessment to be considered suitable. Results: the characteristics assessed by the nurses and the IT professionals, respectively, were considered adequate: Functional suitability (97% and 98%), Reliability (91% and 94%), Usability (89% and 93%), Performance efficiency (97% and 98%), Compatibility (93% and 100%), and System security (95% and 97%). Maintainability (87%) and Portability (97%) were also evaluated by IT professionals. Conclusion: the technical quality of the SACR-O system was considered excellent by nurses and IT professionals.


Objetivo: avaliar a qualidade técnica de um sistema de apoio à decisão para acolhimento e classificação de risco em obstetrícia. Método: estudo metodológico de avaliação de sistema. Foram convidados a avaliarem o Sistema de Acolhimento e Classificação de Risco em Obstetrícia (SACR-O) 12 enfermeiros e 11 profissionais de informática. A partir das normas da Organização Internacional de Normatização se estabeleceu o número mínimo de avaliadores e as características a serem avaliadas: adequação funcional, confiabilidade, usabilidade, eficiência de desempenho, compatibilidade, segurança, manutenibilidade e portabilidade. As características avaliadas deveriam ter avaliação positiva ≥70% para serem consideradas adequadas. Resultados: as características avaliadas por enfermeiros e profissionais de informática, respectivamente, foram consideradas adequadas, a saber: Adequação funcional (97% e 98%), Confiabilidade (91% e 94%), Usabilidade (89% e 93%), Eficiência de desempenho (97% e 98%), Compatibilidade (93% e 100%) e Segurança do sistema (95% e 97%). Por profissionais de informática foram também avaliadas as características de Manutenibilidade (87%) e Portabilidade (97%). Conclusão: a qualidade técnica do sistema SACR-O foi considerada como excelente por enfermeiros e profissionais de informática.


Objetivo: evaluar la calidad técnica de un sistema de soporte de decisiones para la recepción y clasificación de riesgos en obstetricia. Método: estudio metodológico de evaluación del sistema. Fueron invitados a evaluar el Sistema de Recepción y Clasificación de Riesgos en Obstetricia (SACR-O) 12 enfermeros y 11 profesionales de la informática. Con base en las normas de la Organización Internacional de Estandarización, se estableció el número mínimo de evaluadores y las características a evaluar: adecuación funcional, fiabilidad, usabilidad, eficiencia de desempeño, compatibilidad, seguridad, mantenibilidad y portabilidad. Las características evaluadas deberían tener una evaluación positiva ≥70% para considerarse adecuadas. Resultados: las características evaluadas por enfermeros y profesionales de la informática, respectivamente, se consideraron adecuadas, a saber: Adecuación funcional (97% y 98%), Fiabilidad (91% y 94%), Usabilidad (89% y 93%), Eficiencia de desempeño (97% y 98%), Compatibilidad (93% y 100%) y Seguridad del sistema (95% y 97%). Por los profesionales de informática también fueron evaluados las características de Mantenibilidad (87%) y Portabilidad (97%). Conclusión: la calidad técnica del sistema SACR-O fue considerada excelente por los enfermeros y los profesionales de la informática.


Subject(s)
Risk Factors , Nursing Informatics , User Embracement , Health Information Systems , Ambulatory Care , Obstetric Nursing
18.
Rev. latinoam. enferm. (Online) ; 28: e3352, 2020. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1126974

ABSTRACT

Objective: to assess the technical quality of a mobile application to support the nurse's decision to prevent skin lesions in hospitalized newborns, according to the Product Quality Model. Method: a methodological study for technological assessment. The 20 evaluators, divided into two groups, 10 nurses and 10 information technology professionals, used the software, conducted tests based on two case studies, and evaluated six features and 23 sub-features of quality. The assessment was conducted by means of an online form. Data was analyzed through a specific formula and the items that obtained a concordance percentage over 70% were considered adequate. Results: the concordance percentages of the features in the groups of nurses and of information technology specialists were the following: functional adequacy (100%-98.9%), reliability (90%-100%), usability (93.2-85%), performance efficiency (100%-100%), compatibility (97.5-90%), and safety (94%-91%). In the assessment of the sub-features, only accessibility presented a percentage value below the desired one (70%-60%). Conclusion: the software has excellent technical quality to meet the needs of nurses in planning the care for the prevention of skin lesions of hospitalized newborns, brings important advances to neonatal care, contributes to the work process, expands knowledge, and promotes the professional's clinical reasoning.


Objetivo: avaliar a qualidade técnica de um aplicativo móvel para apoiar a decisão do enfermeiro nos cuidados de prevenção de lesões de pele em recém-nascidos hospitalizados, de acordo com o Modelo de Qualidade do Produto. Método: estudo metodológico de avaliação tecnológica. Os 20 avaliadores, divididos em dois grupos, 10 enfermeiros e 10 profissionais da tecnologia da informação, utilizaram o software, realizaram testes a partir de dois estudos de caso e avaliaram seis características e 23 subcaracterísticas de qualidade. A avaliação foi realizada por formulário online. Os dados foram analisados através de fórmula específica e foram considerados como adequados os itens que obtiveram percentual de concordância superior a 70%. Resultados: os percentuais de concordância das características pelo grupo de enfermeiros e de tecnologia foram: adequação funcional (100%-98,9%), confiabilidade (90%-100%), usabilidade (93,2-85%), eficiência de desempenho (100%-100%), compatibilidade (97,5-90%), e segurança (94%-91%). Na avaliação das subcaracterísticas, apenas a acessibilidade apresentou percentual abaixo do desejado (70%-60%). Conclusão: o software apresenta excelente qualidade técnica para atender às necessidades do enfermeiro no planejamento dos cuidados de prevenção de lesões de pele dos recém-nascidos hospitalizados, traz importante avanço para a assistência neonatal, contribui para o processo de trabalho, amplia conhecimentos e fomenta o raciocínio clínico do profissional.


Objetivo: evaluar la calidad técnica de una aplicación para dispositivos móviles destinada a sustentar las decisiones del enfermero con respecto a los cuidados para prevenir lesiones cutáneas en recién nacidos internados, de acuerdo con el modelo de Calidad del producto. Método: estudio metodológico de evaluación tecnológica. Los 20 evaluadores, divididos en dos grupos (uno de 10 enfermeras y otro de 10 profesionales en Tecnología de la Información), utilizaron el software, realizaron pruebas a partir de dos estudios de casos, y evaluaron seis características y 23 subcaracterísticas de calidad. La evaluación se realizó por medio de un formulario en línea. Los datos se analizaron a través de una fórmula específica y se consideraron como adecuados los ítems que obtuvieron un porcentaje de acuerdo superior al 70%. Resultados: los porcentajes de acuerdo de las características que se obtuvieron en el grupo de enfermeras y en el de especialistas en Tecnología de la Información fueron los siguientes: adecuación funcional (100%-98,9%), confiabilidad (90%-100%), facilidad de uso (93,2-85%), eficiencia de rendimiento (100%-100%), compatibilidad (97,5-90%) y seguridad (94%-91%). En la evaluación de las subcaracterísticas, solamente la accesibilidad presentó un porcentaje por debajo del deseado (70%-60%). Conclusión: el software presenta excelente calidad técnica para responder a las necesidades de los enfermeros en cuanto a la planificación de los cuidados para prevenir lesiones cutáneas en recién nacidos internados, aporta un importante avance para la asistencia neonatal, contribuye al proceso de trabajo, expande conocimientos, y fomenta el raciocinio clínico de los profesionales.


Subject(s)
Humans , Male , Pregnancy , Infant, Newborn , Skin , Technology Assessment, Biomedical , Wounds and Injuries , Neonatal Nursing , Disease Prevention , Information Technology , Mobile Applications , Nurses , Nursing Care
19.
Estud. interdiscip. envelhec ; 25(3): 153-166, 2020. tab
Article in Portuguese | LILACS, INDEXPSI | ID: biblio-1416006

ABSTRACT

O objetivo deste estudo foi analisar aplicativos móveis disponíveis nas plataformas Play Store e App Store para cuidadores de idosos no Brasil. Foram analisados aplicativos na língua portuguesa que atuam como instrumentos de auxílio no cuidado ao idoso e/ou que promova a relação comercial entre cuidador de idoso profissional e família. Como resultado da busca, foram encontrados 247 aplicativos que se encaixassem nos perímetros da pesquisa. Após critérios de exclusão, restaram 28 aplicativos que foram organizados em categorias, sendo que dezoito aplicativos apresentaram função de aproximar profissionais/serviços e familiares/idosos, sete para auxílio ao idoso, cuidador profissional ou familiar, três para monitoramento do idoso, quatro para registro de informações do idoso e cinco pertencem a mais de uma categoria. Conclui-se que há aplicativos disponíveis nas lojas virtuais com temas voltados para o cuidado do idoso e que promovem relacionamento entre os familiares e o idoso assistido. Todavia, evidenciou-se a necessidade de inclusão de novas funcionalidades e ajustes para melhoria da usabilidade dos aplicativos.(AU)


The aim of the study was to analyze mobile apps available on the Play Store and App Store platforms, focusing on caregivers of elders in Brazil. The apps will be in the Portuguese language, and also have instruments to assist the elderly and/or promote a commercial rela- tionship between caregiver of the elderly and family. Only 28 out of 247 apps matched the research objectives and were organized into categories, dezoito apps are for bringing professionals or services together and family or older adults, seven are for assisting professional caregiver or family, three are for monitoring older adults; four are for recording the elderly's information and five belong to more than one category. There are apps available in stores with themes focused on the care of elders and promote the relationship between the family. However, there was a need to include new features and adjustments to improve apps.(AU)


Subject(s)
Technology Assessment, Biomedical , Aged , Caregivers , Mobile Applications
20.
São Paulo; s.n; 2020. 135 p
Thesis in Portuguese | LILACS, BDENF | ID: biblio-1398665

ABSTRACT

Introdução: A maioria dos países do mundo está implantando o Registro Eletrônico em Saúde como uma das iniciativas mais importantes em sua política de assistência à saúde, na perspectiva de obter atendimento seguro e de qualidade. No entanto, problemas de usabilidade podem afetar a eficácia, a eficiência e a satisfação do usuário. Objetivo: avaliar a usabilidade de um Sistema de Apoio à Decisão Clínica para documentar o Processo de Enfermagem. Método: estudo quantitativo, desenvolvido em três etapas. A primeira etapa configurou o delineamento quase- experimental, do tipo antes de depois, comparando a qualidade de 81 registros de enfermagem da Versão I do sistema (pré-intervenção) com 58 registros da versão II (pós-intervenção). O instrumento utilizado foi o Quality of Diagnoses, Interventions and Outcomes Q-DIO Versão Brasileira, que possui quatro domínios e escore máximo de 58 pontos. As intervenções consistiram em planejamento e implantação piloto da versão II do sistema, treinamento e acompanhamento dos usuários. A segunda etapa correspondeu à avaliação da eficiência por meio da mensuração do tempo despendido pelo enfermeiro para documentar a Avaliação de Enfermagem e à correlação com os itens da avaliação. Na terceira etapa, foi medida a satisfação dos usuários na utilização da versão II do sistema por meio do questionário Software Usability Measurement Inventory SUMI, cujas escalas possuem escores padronizados com referência a uma média populacional de 50 pontos. Os escores das escalas SUMI foram computados e analisados no software SUMISCO. Os demais dados foram analisados no software R, utilizando estatística descritiva e inferencial. A coleta de dados das três etapas ocorreu entre janeiro de 2019 e janeiro de 2020. Resultados: A média obtida na aplicação do Q-DIO foi 38,24 pontos na versão I e 46,35 pontos na versão II. Houve evidências de diferença estatística entre as médias dos grupos pré e pós-intervenção (valor-p menor que 0,001) e diminuição dos itens não documentados nos quatro domínios avaliados. O tempo médio despendido pelo enfermeiro para documentar a Avaliação de Enfermagem foi de 12,5 minutos, desvio padrão de 11,2 minutos e mediana de 8,9 minutos. A média dos enfermeiros nas escalas SUMI foram: Eficiência 59,58, Satisfação 56,83, Utilidade 55,92, Controle 44,80, Aprendizagem 55,75 e Usabilidade Global 56,00. A média dos técnicos de enfermagem foram: Eficiência 60,42, Satisfação 62,58, Utilidade 60,84, Controle 54,47, Aprendizagem 65,79 e Usabilidade Global 60,68. Conclusões: a qualidade da documentação na versão II do sistema foi superior à versão I. A eficácia do sistema para documentar o Processo de Enfermagem e a efetividade das intervenções foram comprovadas. A avaliação da eficiência identificou o tempo despendido para documentar a Avaliação de Enfermagem. A média na maioria das escalas SUMI ficaram acima do banco de dados de referência internacional, exceto na escala Controle que ficou abaixo do valor médio na avaliação dos enfermeiros. Apontados problemas de usabilidade que podem impactar negativamente na experiência do usuário. Este estudo contribui para a prática clínica, auditoria de qualidade da documentação, visibilidade da enfermagem enquanto ciência do cuidado, desenvolvimento e implementação de sistemas de apoio à decisão clínica funcionais, interativos e amigáveis.


Introduction: most countries in the world have been implementing the Electronic Health Record as one of the most important initiatives of their health care policy, with a view to obtaining safe and quality care. However, usability issues can affect the effectiveness, efficiency and users satisfaction. Objectives: assessing the usability of a Clinical Decision Support System used for Nursing Process documentation purposes. Method: quantitative study developed in three stages. The first stage comprised the adoption of a quasi-experimental design (of the before and after type) comparing the quality of 81 nursing records of Version I of the system (pre-intervention) with 58 records of version II (post-intervention). The instrument used was the Quality of Diagnoses, Interventions and Outcomes - Q-DIO Brazilian Version, which has four domains and a maximum score of 58 points. The interventions consisted of planning and pilot implementing the system version II, users training and monitoring. The second stage comprised efficiency analysis based on the time spent by nurse to document the Nursing Assessment and the correlation with the assessment items. The third stage referred to users satisfaction assessment based on the Software Usability Measurement Inventory - SUMI questionnaire, whose scales have standardized scores with reference to a population average of 50 points. The scores of the SUMI scales were computed and analyzed using the SUMISCO software. The other data were analyzed using R software, and descriptive and inferential statistics. Data collection for the three stages took place between January 2019 and January 2020. Results: The average Q-DIO scores reached 38.24 points (in version I) and 46.35 points (in version II). There was evidence of statistical difference between the means of the pre and post- intervention groups (p-value less than 0.001) and a decrease in the undocumented items in the four domains evaluated. The mean time spent by nurse to document the assessment in the system was 12.5 minutes (standard deviation = 11.2 minutes and median = 8.9 minutes). Nurses recorded the following averages: Global Usability (56.00), Efficiency (59.58), Affect (56.83), Helpfulness (55.92), Control (44.80) and Learnability (55.75). Nursing technicians recorded the following averages: Global Usability (60.68), Efficiency (60.42), Affect (62.58), Helpfulness (60.84), Control (54.47) and Learnability (65.79). Conclusion: the quality of the documentation in version II of the system was superior to version I. The effective of the system to document the Nursing Process and the effectiveness of interventions were proven. The efficiency analysis identified the time spent to document the Nursing Assessment. The average recorded in most SUMI scales was higher than that of the international reference database, except for the Control scale, which recorded below-the-average value in the nurses evaluation. Usability issues pointed out may negatively affect the user experience. This study contributes to clinical practice, documentation quality audit, visibility of nursing as a science of care, development and implementation of functional, interactive and friendly support systems for clinical decision.


Subject(s)
Technology Assessment, Biomedical , Decision Support Systems, Clinical , Nursing Process , Nursing Informatics , Electronic Health Records , Standardized Nursing Terminology
SELECTION OF CITATIONS
SEARCH DETAIL